BPS-C(6501EA1001C)
LG top loading washing machine water level replacement 6501EA1001C
parameter
1. Rated voltage: DC5V;
2. Action water level: Environment temperature of 20℃, the temperature gradient of ±0.6mm/℃, the cover of water level sensor is down, changing rate of the water level is V=1-2mm/sec;
3. No leakage under air pressure of 7.5kPa;
4. Conduct test of sensor service life with speed of 20times/min under rated pressure, no exception with successive operation of 6000 times, before the test, the variation of water level is under 10mm;
5. Breakaway torque of adjusting the screw is not less than 3.9N.cm;
6. Insulation resistance: not less than 100MΩ, not less than 10MΩ after moisture (with temperature of 40±3℃, humidity of 90-95 % for 24 hours);
7. Environmental water level changes: Placed under environment with temperature of 0℃, 40℃, 60℃ and humidity of 90-95% for 168 hours, then keep it under room temperature of 20℃ for 4 hours, and measure the water level change below 10mm (test and measure under temperature of 0℃).